https://w3id.org/omop/ontology/has_unit
For Dose Era: The Concept Id representing the unit of the specific drug ingredient. - For Measurement: At present, there isn't a prescribed unit for individual measurements, such as Hemoglobin A1C, meaning it's not obligatory to express these measurements as a percentage. UNIT_SOURCE_VALUES should be linked to a Standard Concept within the Unit domain that most accurately reflects the unit provided in the source data. If the source data does not include units, set UNIT_CONCEPT_ID to NULL. If units are provided but not mapped, set UNIT_CONCEPT_ID to 0. Otherwise, map the units to a CONCEPT_ID. Remember that units are case-sensitive in vocabulary. - For Specimen: The unit for the quantity of the specimen. Map the UNIT_SOURCE_VALUE to a Standard Concept in the Unit domain. [Accepted Concepts](https://athena.ohdsi.org/search-terms/terms?domain=Unit&standardConcept=Standard&page=1&pageSize=15&query=). If the source unit is NULL (applicable to cases when there's no numerical value or when it doesn't require a unit), keep unit_concept_id NULL as well. If there's no mapping of a source unit, populate unit_concept_id with 0. - For Device Exposure: UNIT_SOURCE_VALUES should be mapped to a Standard Concept in the Unit domain that best represents the unit as given in the source data. There is no standardization requirement for units associated with DEVICE_CONCEPT_IDs, however, it is the responsibility of the ETL to choose the most plausible unit. If the source unit is NULL (applicable to cases when there's no numerical value or when it doesn't require a unit), keep unit_concept_id NULL as well. If there's no mapping of a source unit, populate unit_concept_id with 0. - For Observation: There is currently no recommended unit for individual observation concepts. UNIT_SOURCE_VALUES should be mapped to a Standard Concept in the Unit domain that best represents the unit as given in the source data. There is no standardization requirement for units associated with OBSERVATION_CONCEPT_IDs, however, it is the responsibility of the ETL to choose the most plausible unit. If the source unit is NULL (applicable to cases when there's no numerical value or when it doesn't require a unit), keep unit_concept_id NULL as well. If there's no mapping of a source unit, populate unit_concept_id with 0.
| DOMAIN | PROPERTY | RANGE |
|---|---|---|
| Blank node (see implementation) | Has unit | Concept |
@prefix omop: <https://w3id.org/omop/ontology/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix owlready: <http://www.lesfleursdunormal.fr/static/_downloads/owlready_ontology.owl#> .
@prefix rdf: <http://www.w3.org/1999/02/22-rdf-syntax-ns#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
omop:has_unit a owl:FunctionalProperty,
owl:ObjectProperty ;
rdfs:label "Has unit"^^xsd:string ;
owlready:python_name "unit"^^xsd:string ;
rdfs:comment "For Device Exposure: UNIT_SOURCE_VALUES should be mapped to a Standard Concept in the Unit domain that best represents the unit as given in the source data. There is no standardization requirement for units associated with DEVICE_CONCEPT_IDs, however, it is the responsibility of the ETL to choose the most plausible unit. If the source unit is NULL (applicable to cases when there's no numerical value or when it doesn't require a unit), keep unit_concept_id NULL as well. If there's no mapping of a source unit, populate unit_concept_id with 0."@en,
"For Dose Era: The Concept Id representing the unit of the specific drug ingredient."@en,
"For Measurement: At present, there isn't a prescribed unit for individual measurements, such as Hemoglobin A1C, meaning it's not obligatory to express these measurements as a percentage. UNIT_SOURCE_VALUES should be linked to a Standard Concept within the Unit domain that most accurately reflects the unit provided in the source data. If the source data does not include units, set UNIT_CONCEPT_ID to NULL. If units are provided but not mapped, set UNIT_CONCEPT_ID to 0. Otherwise, map the units to a CONCEPT_ID. Remember that units are case-sensitive in vocabulary."@en,
"For Observation: There is currently no recommended unit for individual observation concepts. UNIT_SOURCE_VALUES should be mapped to a Standard Concept in the Unit domain that best represents the unit as given in the source data. There is no standardization requirement for units associated with OBSERVATION_CONCEPT_IDs, however, it is the responsibility of the ETL to choose the most plausible unit. If the source unit is NULL (applicable to cases when there's no numerical value or when it doesn't require a unit), keep unit_concept_id NULL as well. If there's no mapping of a source unit, populate unit_concept_id with 0."@en,
"For Specimen: The unit for the quantity of the specimen. Map the UNIT_SOURCE_VALUE to a Standard Concept in the Unit domain. [Accepted Concepts](https://athena.ohdsi.org/search-terms/terms?domain=Unit&standardConcept=Standard&page=1&pageSize=15&query=). If the source unit is NULL (applicable to cases when there's no numerical value or when it doesn't require a unit), keep unit_concept_id NULL as well. If there's no mapping of a source unit, populate unit_concept_id with 0."@en ;
rdfs:domain [ a owl:Class ;
owl:unionOf ( omop:Measurement omop:DeviceExposure omop:Observation omop:Specimen omop:DoseEra ) ] ;
rdfs:range omop:Concept ;
omop:omop_cdm_name "device_exposure.unit_concept_id#131 AS Concept"^^xsd:string,
"dose_era.unit_concept_id#315 AS Concept"^^xsd:string,
"measurement.unit_concept_id#144 AS Concept"^^xsd:string,
"observation.unit_concept_id#167 AS Concept"^^xsd:string,
"specimen.unit_concept_id#222 AS Concept"^^xsd:string .